Exposure D is for any building within 1, ft of a large open area that is at least a mile wide, or any building that is above 60 ft tall no matter the location. Certain important infrastructure buildings like schools and hospitals must meet Exposure D requirements no matter their size or location. Finally, within a single building, there are 2 different zones; zone 4 and zone 5.
This is because the corners of buildings experience stronger forces from wind and flexion from the building moving during a storm. These zones are determined by the length of a single wall. For example, for a wall measuring 20 ft, any opening within 2 ft of the corners would be considered zone 5 and need higher design pressures.
So, what do these requirements mean for you? First and foremost, the specific FBC requirements for your building will determine what design pressures DPs your new products, whether they are hurricane shutters or impact windows and doors, must meet. All these products must undergo both missile testing, which determines impact resistance, as well as cyclical testing.
These DP ratings refer to how much pressure, measured in pounds per square foot psf , that the product can withstand before it breaks or is altered beyond acceptable parameters. If your building is required to have high DPs, sometimes negative DP values for high-rises can be as high as psf, you may become more limited in size or material types for your hurricane protection.
To meet the changing demands of the Florida Building Code, manufacturers are constantly innovating to create larger and stronger products.
The Florida Building Code can be complicated to understand for those with little or no experience dealing with it. If you are considering new impact windows and doors, it is recommended that you speak with a seasoned professional who understands all these requirements and has access to a variety of product options to meet the demands of the FBC.
We service several counties on the East Coast including; St. Lucie, Martin, and Palm Beach. Email: Inquiry thereplacementcompany. Your information is secure with us! Privacy Policy. How Can I Get an Estimate? Exceptions may be made for openings less than 3 inches in diameter in doors or decorative glass and glazing provided with a protective bar. The IRC requires window mullions to undergo testing or structural calculations to demonstrate the ability to meet structural requirements.
In both the IECC and IRC, replacement windows must comply with the energy conservation requirements for fenestration in new construction, regardless of what the replacement is. WOCDs must also be used on replacement windows if it would be required for that location on new construction. The thermally isolated sunroom must be separated from the remainder of the building by exsiting exterior wall construction, or construction that adheres to the IECC requirements for exterior walls.
The sunroom must also be equipped with their own heating or cooling systm, or the ability to be controlled as a separate zone on the thermostat. An exemption may be made for exterior windows and doors that are tested and labeled in accordance with NAFS Factory-built unit skylights must adhere to the following requirements: Skylights intended to be installed in a single roof opening without intermediate framing must be tested and labeled in accordance with NAFS Skylights subject to snow load, wind and dead load are permitted to be evaluated for different positive and negative design pressures.
Note: The above information is a summary of the major requirements recently published in the I-codes, this is not a full listing of all updated requirements. Especially in any room used for sleeping purposes, it will require its own egress window. Remodeler: if you have an existing home and you add a sleeping room, or finish a separate living space in the basement, the code requires that you install an egress window to serve these spaces.
Without a means of egress, these rooms can represent a dangerous fire trap if you do not have a quick and easy to operate emergency egress escape window. If you have a basement that has a bedroom, recreation room, den, family room, media room, office, or home gym. All of these rooms are required to have a means of egress.
The bottom of the egress window opening can't exceed 44" from the finished floor. The minimum opening area of the egress window is 5. The minimum egress window opening height is 24" high. The minimum egress window opening is 20" wide. Egress window wells are required where the bottom of the egress window is below ground level.